Installation
Leave at least 1 inch
of clearance between
the unit and the
inside walls of the
enclosure.
The temperature at
the unit intake vent
must never exceed
104°F (40°C).

Setting Up LocalView

30
Figure 2-4
Rapid Eye Multi-Media LT Unit Air Circulation
Cable space required at the back of the unit.
There are exhaust vents
on both sides of your
Multi-Media LT unit.
Caution
Units that are operating in an environment where the ambient temperature
measured at the intake vent is greater than 104°F (40°C) are not covered
by Honeywell warranty.
Caution
Moisture condensation could damage the DVR. Be aware of possible
moisture condensation when using the unit in a humid area, or in areas
where the temperature fluctuates. Also be aware of possible condensation
when moving units between rooms with extreme temperature changes.
A PC mouse (included) and PC monitor (not included) are needed when using LocalView
to operate a Rapid Eye Multi-Media LT DVR. LocalView is available while the DVR is running.
Exhaust and intake
vents on the unit and
enclosure should line
up for proper air
circulation.
1 inch