Cast Bypass Top Plate Removal - Regency Fireplace Products CI2600 Owners & Installation Manual

Wood fireplace insert
Hide thumbs Also See for CI2600:
Table of Contents

Advertisement

CAST BYPASS TOP PLATE REMOVAL /

INSTALLATION
1. Allow the stove to burn out and cool down, until cool to touch.
2. Open stove door to access secondary air tube.
3. Remove secondary air tube–(see previous page).
4. Remove 2 bolts in locations shown and remove stainless steel front lip.
retainer.
View of inside top of stove
5. 8 bolts secure the cast bypass top plate to the roof of the stove.
Before removing the bolts securing the cast bypass - support the cast up
with
2 X 12-1/4" 2 x 4 's. The cast bypass opening weighs 30lbs - DO
NOT REMOVE the bolts on the cast bypass prior to supporting the weight
to avoid damage and injury.
View of inside top of stove
6. Remove the cast bypass opening top plate and replace.
7. Reverse steps to reinstall.
maintenance
Stainless front lip retainer
Cast bypass opening
| 37