OVERSIZE CAST FACEPLATE INSTALLATION

OVERSIZE CAST FACEPLATE INSTALLATION
Remove unit door prior to installation of faceplate.
Remove and lay out all contents from the faceplate package.
1. Remove bypass ring and rod by turning counter clockwise - set aside.
2. Install tool and handle holder (use part packed with Faceplate - not part
from Manual pack) to the left side of the unit with one - 7/16" bolt as
shown below. (Note: part is packed with the Oversized Faceplate pack-
age).
3. Identify left and right side panels
Right Panel/ Back Side
919-411
CI2600/HI400 | wood insert
Handle / Tool holder
Left Panel/ Back Side
4. Remove 8-7/16" bolts in locations shown below and Install the left and
right of the fascia panels using four 7/16'' bolts.
NOTE: Fan cassette must be installed prior to this step. See fan install
instructions.
Fascia side panels installed with Bolts
5. Install fan defl ector on unit. If screw holes not present on unit, lineup
defl ector with bypass rod opening and ensure defl ector is level. Secure
with 2 supplied screws in locations shown below.
If screw holes already present on unit, line up defl ector with corre-
sponding screw holes and secure with 2 screws on locations shown
below.
Fan defl ector screw locations