BYPASS DOOR GASKET REPLACEMENT

1. Remove Bypass Rod - turn counter clockwise.
2. The following parts must be removed to allow access and a positive connection.
a)
Primary Air Shield
b)
Combustor Flame Shield
c)
Combustor
d)
Upper shield
A -Primary Air Shield - loosen 2 x 7/16"
bolts - slide forward to remove.
B- Combustor Flame Shield - loosen 2 x 7/16"
Bypass Rod
bolts to remove.
D - Combustor- remove with pliers
Tilt down and forward to ease removal.
E - Upper Shield - slide forward and lift up to remove.
3. Lift off bypass plate, remove bypass gasket and replace with a new one.
maintenance
Bypass plate
Bypass gasket