Table 3-18. Utility 2 Interface Pin/Signal Descriptions (J13)

Pin # Signal
1
LIDSW
2
PWRBT*
3
BATLOW*
4
NC
5
IRTX
6
IRRX
7
GND
8
VCC
9
MDATA
10
MCLK
11
GND
12
VCC
13
SMBCLK
14
SMBDATA
15
USBPWR1
16
USBPWR2
17
USBP1-
18
USBP2-
19
USBP1+
20
USBP2+
21
USBGND1
22
USBGND2
23
SHIELD1
24
SHIELD2
Notes: The shaded area denotes power or ground. The signals marked with * = Negative true logic.
48
I/O
Description
-
Lid Switch – This signal (Suspend Status on I/O Hub) is asserted by the
I/O Hub to indicate the system will be entering a low power state soon.
This signal is not shared with other devices on the LittleBoard. This
signal is similar to the Lid Switch on laptop computer.
I
Power Button – This signal from an external switch to the I/O Hub is
not used with AT Power supplies.
Battery Low – This signal from external battery indicates to the I/O Hub
there is insufficient power to boot the system.
O
Not connected (IR Mode select)
O
IR Transmit Data – This signal goes to external IrDA Transceiver.
I
IR Receive Data – This signal comes from external IrDA Transceiver.
-
Ground
-
+5 Volts
I/O
Mouse Data – Data signal provided to external mouse connector.
I/O
Mouse Clock– Clock signal provided to external mouse connector
-
Ground
-
+5 Volts
-
SMBus Clock – Clock signal provided to external devices.
-
SMBus Data – Data signal provided to external devices.
-
+5V USB Port Power – Port is disabled if this input is low.
-
+5V USB Port Power – Port is disabled if this input is low.
I/O
USB 1 Negative Data Signal
I/O
USB 2 Negative Data Signal
I/O
USB 1 Positive Data Signal
I/O
USB 2 Positive Data Signal
-
USB Port ground
-
USB Port ground
-
USB Port shield (Cable Shield)
-
USB Port shield (Cable Shield)