H D D E V E N; Alarm Out - Ganz Digimaster Series DR8HRD Instruction Manual

Digimaster series
Table of Contents

Advertisement

SYSTEM SETUP
EVENT / SENSOR - ALARM OUT
This menu will determine the behavior and actions that will trigger each of the 1 alarm output.
Behavior settings
ALARM OUT: Choose which alarm output to configure.
OPERATION: The selected alarm output can be enabled or disabled.
MODE: Can be either set as 'TRANSPARENT' (the output is active only when the trigger criteria is present)
or 'LATCHED' (the output is active for a set period of time after the trigger).
DURATION: In 'LATCHED' mode, the amount of time that the alarm output remains active after it has been triggered.
TYPE: Can be set to high (0V to +5V when activated) or low (+5V to 0V when activated).
HDD EVENT: Determines whether a hard drive event will trigger an alarm output.
Action settings
ALARM: Determines whether the specific channel alarm input would trigger the alarm output.
VIDEO LOSS: Determines whether video loss on any of the selected channels will trigger the alarm output.
MOTION: Determines whether motion detection on any of the selected channels will trigger the alarm output.
NOTE: Remember to select 'APPLY' and press 'ENTER' to save all settings before exiting these menus.
Click on the ALARM OUTPUT menu, and click on a field.
Use the
button to modify the value.
46

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dr16hrd

Table of Contents