Maintenance Charts - Jacobsen Greens King V Plus Service Manual

Hide thumbs Also See for Greens King V Plus:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
6
MAINTENANCE & LUBRICATION
GB

6.3 MAINTENANCE CHARTS

Air Filter
Battery Charge
Belts
Brake
Cooling System
Electrical System
Engine Oil
Engine Oil Filter
Fuel System
Fuel Filter
Grease Fittings, All
Hydraulic Hoses and Tubes
Hydraulic Oil
Hydraulic Oil Filter
Muffler and Exhaust
Radiator Screens
Tyres
A - Add or Adjust C - Clean I - Inspect L- Lubricate R - Replace AR - As Required
*
Indicates initial service for new
machines.
**
Or every two years whichever comes
first.
***
Inspect visible hoses and tubes for leaks
or oil marks.
GB-24
Recmmended Service ans Lubrication Intervals
Every
Every
Every
8-10
50
100
Hours
Hours
Hours
I
AR
I
I - A
I - A
I - A*
I - C - A
I*
I
R*
R
R*
R
I
L
L
L
I***
I - A
I
R*
I
I - C/AR
I - A
JACOBSEN GREENS KING V PLUS
MAINTENANCE AND PARTS MANUAL
Every
Every
Every
250
400
500
Hours
hours
hours
R
A
I
R
L
I
R**
R
I
I
Manual grease gun with NLGI Grade 2
(Service Class LB).
II
Engine Oil - See Section 4.3
III
Use Shell Donax TA
IV
Capacity: 2.8 liters 50/50 water ethylene
glycol mix
Every
See
1000
Yearly
Section
Hours
R
4.5
4.8
3.2
3.3
R
4.17
4.14
4.3
4.7
4.7
6.2
4.11
4.12
4.13
4.15
4.17
4.18
Lubrica-
nt
Type
IV
II
II
I
III

Hide quick links: