SUPERSERVER 8027R-TRF+/7RFT+ USER'S MANUAL
3-3

Control Panel LEDs

The control panel located on the front of the chassis has several LEDs (see
Figure 3-1). These LEDs provide you with critical information related to different
parts of the system. This section explains what each LED indicates when illuminated
and any corrective action you may need to take.
Power
Overheat/
Fail
Fan Fail
LED
LED

Power Fail

Indicates a power supply module has failed. The second power supply module will
take the load and keep the system running but the failed module will need to be
replaced. Refer to Chapter 6 for details on replacing the power supply. This LED
should be off when the system is operating normally.

Universal Information LED

When this LED blinks red quickly, it indicates a fan failure and when blinking red
slowly a power failure. The LED will be blue when used for UID (Unit Identifi er).
When on continuously it indicates an overheat condition, which may be caused by
cables obstructing the airfl ow in the system or the ambient room temperature being
too warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain fl ashing or on as long as the indicated condition exists.
See the table below for descriptions of the LED states.
Figure 3-1 Front Panel LEDs and Buttons
HDD
NIC
LED
LED
Power
Reset
LED
Button
3-2
Power
Button