The following installation instructions are for a left handed version of the appliance, when
installing the right handed version dimensions and other references will need to be reversed.
NOTE
GAS & ELECTRICAL SUPPLIES
Gas Supply
A suitable gas supply needs to be provided
to the Left hand end of the appliance at the
lower front corner of the installation cavity.
The pipe sizing should be calculated to
supply at least 40 MJ/h
Allow sufficient pipe penetration to make the
connection as shown right.
The gas inlet access point
for this appliance is provided
NOTE
with a set of flaps to allow
consumer piping with fittings
attached to be passed through
for connection.
For vermin control ensure that
these flaps are closed again
once the piping has been
installed.
Use the supplied gas connection kit (200mm
3/8 Flexi tube with plug and 3/8" - 1/2"
reducing flare connector) to connect the
appliance to the consumer piping.
Electrical Supply
The appliance is supplied with a power
lead (approx. 1.8m long). This needs to be
connected to an isolating wall socket within
the cavity and connected to an isolating wall
switch, preferably located to the left of the
appliance, facing into the room, not inside
the framing cavity.
If a power failure occurs while
the appliance is in operation
NOTE
and if the wall switch is left
in the 'ON' position, when the
power is restored the appliance
will then automatically restart.
Provision of a latched relay (or
other automated power supply
cut off) can be used to prevent
the appliance from restarting,
refer to "Wiring Diagrams" on
page 21 for further details in
regards to latched relays.
This supply is used to isolate all power from
appliance. The power cord is designed for
a 230/240V AC 10 amp supply. Electrical
connections must be in accordance with AS/
NZS 3000 and installed by an authorised
person.
Rinnai
B
A
189 min.
A
Open Side
B
Glass Side
This access hole is only
used when installing a
right handed applaince
Open the hole cover
plates to fit consumer
pipe and flexi tube
Consumer pipe
1/2" flare nut
1/2" - 3/8" flare
reducer
3/8" flared flexi tube
200mm long
10
A
1982 max. over wall lining
B
Close the hole cover
plates over consumer
pipe and lock in place
Appliance
connection
point
A
58 from
finished lining
RF1800 OIM