FINAL CHECKS

Check that the appliance operates properly making sure that all the supplied parts are used and properly installed.
It is important that the customer is fully aware of how to operate the appliance properly and safely. Advise the
customer to fully read the operation sections of this manual to understand how to get the best out of their appliance.
Advise the customer of the need for regular servicing in order to maintain the warranty.
Complete the Commissioning Checklist.

TROUBLE SHOOTING

Symptom
Appliance does
not start
(no spark noise)
Appliance is sparking
then stops (no flames)
Gas supply turned off/empty
Flame starts but spark
keeps going
Flame starts but
then goes out
Appliance goes out
*
If the appliance fails to ignite after four (4) attempts, turn off the power and gas if possible and arrange for a service call or contact
the installer if the unit is newly installed.
Owner corrective action is the same as that of an installer, all other corrective actions are for authorised persons only!

COMMISSIONING CHECKLIST

TO BE COMPLETED BY THE INSTALLER
Serial Number
Installers Name
Installers License No.
Installers Contact No.
Certificate Of Compliance No.
Installation Date
1.
Is the appliance positioned in a suitable location with regards to clearances?
2.
Is the unit fixed in location?
3.
Have all gas connections been checked for leaks using a soapy water solution?
4.
Have you instructed the owner of the correct operation of this appliance before leaving?
5.
Have you left the operating instructions with the owner?
6.
Have you removed all PVC plastic coating material?
Ensure all PVC plastic coating material is removed before operating the unit.
If you have answered NO to any of the above questions you MUST NOT allow the appliance to be
WARNING
operated until the item has been rectified.
Rinnai
Possible Cause(s)
Mains power disconnected
Gas control locked out
Faulty spark electrode
Power fuse blown
Air in gas pipe
Faulty flame rod
Wind blowing on burner
Faulty flame rod
Wind blowing on burner
Gas supply 'Off' or empty
Power supply turned off
Wind blowing on burner
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
__________/__________/__________
Owner Actions
Check mains supply and isolating switch are 'On'
Service call
Check Electrode is not touching the bracket
Service call
Service call
Turn on gas supply or change bottles *
Service call
Check flame rod is not touching the bracket
Service call
Check flame rod is not touching the bracket
Check gas supply or change/replace bottles
20
Installer Actions
Switch 'Off' and 'On' again *
Check HT lead
Replace fuse
Purge gas pipes *
Check flame rod lead
Prevent excessive draft on burner
Check flame rod lead
Prevent excessive draft on burner
Check power is on
Prevent excessive draft 'On' burner
NO
YES
RF1800 OIM