Service Adjustment Data Table (Factory Set Data List) - Sanyo PLV-HD2000N Service Manual

Hide thumbs Also See for PLV-HD2000N:
Table of Contents

Advertisement

Electrical Adjustments

Service Adjustment Data table (Factory Set Data List)

CAUTION : These initial values are the reference data written from the CPU ROM to the memory IC when the new
memory IC replaced. The adjustment items indicated with "✽" are required to readjust following to the
"Electrical adjustments". Other items should be used with the initial data value.
Group
Item
No.
No.
S
0
Temperature Monitor Indication
0
LM76 (Temp) Monitor
1
LM76 (Temp) Monitor
2
Thermistor Monitor
3
Thermistor Monitor
S
1
Pressure Monitor Indication
0
MPXA4114A(Pressure) Monitor
1
MPXA4114A(Pressure) Monitor
2
MPXA4114A(Pressure) Monitor
3
MPXA4114A(Pressure) Monitor
S
8
Frequency Counter Monitor
0
SW FPGA No Signal
1
SW FPGA H Counter
2
SW FPGA V Counter
S
10
RS232C Set
0
Baud rate
1
RTS/CTS Flow Control
2
CTS Timeout Second
3
Serial Address
S
11
LAN Setting (Option)
0
LAN Card Switch
S
20
Logo On/Off
0
Logo On/Off
S
30
Color Shade Compensation
0
Compensation On/Off
S
40
Dimmer Control
0
Dimmer On/Off
1
Dimmer Level
S
50
Auto Picture Control
0
Auto Picture On/Off
S
80
Factory use
0
Factory use
S 112
Lamp Config
0
Lamp Config Change
S 113
Lamp Reset Counter
0
Lamp1 Reset Times
1
Lamp2 Reset Times
2
Lamp3 Reset Times
3
Lamp4 Reset Times
S 115
Lamp Go Out
0
Lamp Go Out
S 120
RC KEY Disable
0
RC Zoom & Focus Only
1
RC / KEY All
2
Process after Power Fail
S 140
Fan Output Level
0
Fan A Min
1
Fan A Max
2
Fan C Min
3
Fan C Max
4
Fan B Min
5
Fan B Max
6
Fan D1 Min
7
Fan D1 Max
8
Fan D2 Min
9
Fan D2 Max
10
Fan D3 Min
11
Fan D3 Max
12
Fan D4 Min
13
Fan D4 Max
S 141
Fan Output Level
0
Fan Output Level
S 150
Factory Set (Reset)
0
Factory Set Do not touched.
ITEM
Temp. Sensor (Intake)
Temp. Sensor (Inner)
Temp. Thermistor (Inner)
Temp. Thermistor (Inner) DAC value
Pressure Sensor
Pressure Sensor [mmHg]
Pressure Sensor [hPa]
Pressure Sensor [kPa]
RS232C Baud rate (0 : 9600 / 1 : 19200)
RS232C RTS/CTS Flow Control (0 : Disable / 1: Enable)
RS232C CTS Timeout
Individual address in RS–232C chain connection
LAN (0 : Disable / 1: Enable)
(0 : Menu Operation / 1 : Prohibition)
(0 : Off / 1 : On)
(0 : Menu Operation / 1 : Off)
(0 : 200W ~ 15 : 250W)
(0 : Menu Operation / 1 : Off)
Lamp Monitor Time Set (Step : 500h)
0 : Enable / 1 : Disable
0 : Enable / 1 : RC Disable / 2 : KEY Disable
0 : Not Recover by KEY / 1 : Recover by KEY
(✽) Fan A Driving Voltage Adj. at TP7611
(✽) Fan A Driving Voltage Adj. at TP7611
(✽) Fan C Driving Voltage Adj. at TP2661
(✽) Fan C Driving Voltage Adj. at TP2661
(✽) Fan B Driving Voltage Adj. at TP2671
(✽) Fan B Driving Voltage Adj. at TP2671
(✽) Fan D1 Driving Voltage Adj. at TP2631
(✽) Fan D1 Driving Voltage Adj. at TP2631
(✽) Fan D2 Driving Voltage Adj. at TP2632
(✽) Fan D2 Driving Voltage Adj. at TP2632
(✽) Fan D3 Driving Voltage Adj. at TP2633
(✽) Fan D3 Driving Voltage Adj. at TP2633
(✽) Fan D4 Driving Voltage Adj. at TP2634
(✽) Fan D4 Driving Voltage Adj. at TP2634
0 : Max / 1 : Factory / 2 : Auto / 3 : Min
Available at No.10 caution : Important! Do not attempt.
Function
–88–
Initial Value
Data
Range
HD2000
0 / 1
1
0 / 1
0
0 ~ 255
0
0 ~ 999
1
0 / 1
0
0 / 1
0
0 / 1
1
0 / 1
1
0 ~ 15
15
0 / 1
1
1000 ~ 8000
1500
0
0
0
0
0
0 / 1
0
0 / 1 / 2
0
0 / 1
0
0 ~ 255
229
0 ~ 255
20
0 ~ 255
215
0 ~ 255
15
0 ~ 255
195
0 ~ 255
25
0 ~ 255
112
0 ~ 255
65
0 ~ 255
112
0 ~ 255
65
0 ~ 255
112
0 ~ 255
65
0 ~ 255
112
0 ~ 255
65
0 ~ 3
2
0 ~ 10
0