Sanyo PLV-HD2000N Service Manual page 35

Hide thumbs Also See for PLV-HD2000N:
Table of Contents

Advertisement

8
-3
Mains switch Unit removal.
1. Remove 4 screws-A and remove the Main-SW Unit.
2. Remove 2 screws-B and remove the Lamp Cover Switch(SW902).
3. Remove 2 screws-D and remove the AC Inlet.
4. Unhook the stoppers and remove the Mains Switch(SW901).
Push part(a) and pull the Main Switch.
5. Remove 2 screws-C and remove the Noise Filter.
(See Fig.8-3, 8-3a)
To remove the Fuse.
PLV-HD2000E
Turns the fuse holder cover with the slot screw driver.
Remove the fuse and the fuse holder cover upward.
MAIN-SW Unit
PLV-HD2000N
Remove the fuse and the fuse holder cover forward.
Fuse holder
cover
Fuse
Fuse holder
Fig. 8-3b
- 35 -
Mechanical disassemblies
SW902
B
B
C
A A
A
A
C
Hook (a)
Noise Filter
LF901
Fig. 8-3
Fuse holder
Fuse
Fig. 8-3c
Holder
AC Inlet
D
(a)
D
SW901
Fig. 8-3a
Fuse holder
cover