Optical adjustments
Fig. 60d
TO REMOVE ADJUSTMENT TOOL
After completing the adjustment, remove the Adjustment Tool as follows.
1. Loosen 2screws-B and release LCD Panel Bracket.
Remove 2screws-C, then remove Adjustment Tool.
2. Slide the Adjustment Tool, and release from the LCD Panel Bracket.
3. Remove the Adjustment Tool upward.
See Fig.60d,60e
Loosen 2 Screws-B before remove
Screw-B
Adjustment Tool
Loosen 2 Screws-C
before remove
Screw-C
Prism/LCD Panel
unit
Step 1
Guide
Screw-B
Slide the
adjustment tool
Step 2
- 74 -
Screw-C (M4 X 6)
(included with Adjustment Tool)
Convergence Adjustment Tool
The figure is an installation figure
for the adjustment of the Blue
LCD panel.
Step 3
Fig. 60e