Optical Unit disassemblies
12
-3
Optical filters and Polarized glasses disassemblies.
1. Remove 3 screws-A and remove the stoppers.
2. Remove the plate.
3. Remove the polarized glasses and remove the optical filters upward.
(See Fig.12-3)
Note:
Each polarizer glasses use different characteristic polarization glasses. Mark the polarizer units as they are
removed from the optical unit so that they may be reassembled in the same location from which they were
removed.
Fig.12-3
A
Plate
Glass should be placed as the film attached side comes to the LCD panel side.
Printed marker Comes top side. (Optical filter)
A