Group-no.
0 - 0
Temperature monitor IC5801 Read only
0 - 1
Temperature monitor IC1519 Read only
1 - 0
Atmospheric Pressure monitor
10 - 0
RS232C Baud rate (0:9600 / 1:19200)
10 - 1
RS232C RTS/CTS Flow Control (0:Disable / 1:Enable)
111 - 0
Lamp-1
111 - 1
Lamp-2
111 - 2
Lamp-3
111 - 3
Lamp-4
930 - 0
Lamp mode
930 - 1
Lamp mode
930 - 2
Lamp mode
998 - 0
Grid Test Pattern Display
Note :
Group No. 930
■ If the data value appears "11" on the screen, the lamp mode is
selected.
■ If the data value appears "0" on the screen, the lamp mode is
not selected. Set the data value to "10."
■ If the data value appears "99" on the screen, it is period for
cooling of the lamp.Wait until it is changed to "0." Then set the
data value to "10."
Caution :
Other adjustment items are
not related to service and a
maintenance. Don't change
the data values of those
adjustment items. Otherwise
it may cause loss of product
safety.
Test Points Location
Please refer to "Printed
Wiring Board Drawings." for
the locations of test point.
Adjustment Item
IC4849 Read only
Lamp lighting time
Read only
Lamp lighting time
Read only
Lamp lighting time
Read only
Lamp lighting time
Read only
4 Lamp Mode
Lamp 1-4 of 2 Lamp Mode
Lamp 2-3 of 2 Lamp Mode
FN903
Adjustment Mode
Not designated
(See Note.)
(See Note.)
(See Note.)
Note : Fan control Group No. 140
Group Fans A: FN903, 904, 905, 916
Group Fans B: FN909, 910, 911, 912
Group Fans C: FN901, 906, 907,908, 913, 914, 915
Group Fans D: FN917, 918, 919, 920
FN920
FN919
FN909
FN917
FN904
FN905
-81-
Electrical Adjustments
DVI
COMP.
SDI
FN918
FN910
FN901
FN913
FN916