4. Start the RFA application from the RFA information page. To create and download the license file and
authentication file, follow the instructions outlined in the Avaya Remote Feature Activation (RFA) User
Guide, 03-300149.
5. Use the download or e-mail capabilities of the RFA web site to download the license and
authentication files to your laptop.

Preparing the INADS IP address

The INADS IP address is required in order to configure the S8300's modem for alarming. If you are
preparing a G350 with an S8300 for a remote installation, you must first obtain an INADS IP address. Use
the Automatic Registration Tool (ART) to obtain an IP address for an INADS alarming modem.
1. Access the ART Web site on your laptop at http://art.dr.avaya.com.
2. Select Administer S8x00 Server products for installation script, and then log in.
3. Enter the customer information, select Installation Script, and click Start Installation script & IP
Addr Admin. A script file is created and downloaded or e-mailed to you.

Preparing Needed Hardware

Laptop – to configure the Avaya G350 Media Gateway, you need to prepare a laptop with a serial port.
The laptop must have Internet Explorer installed. If you install a G350 without an S8300, you must
prepare the laptop with a Windows 2000 or Windows XP operating system and a TFTP server.
Modem – in order to set up a remote configuration of the G350, you must prepare a USB modem.
Currently, the G350 supports the MultiTech USB modem, model MT5634ZBA-USB-V92. If a USB
modem is not available, you can also use a serial modem, the Multitech MultiModem ZBA,
MT5634ZBA-V92.

Preparing Tools Needed for Mounting

To mount on a rack or wall, prepare a Phillips head screwdriver.
To mount on a wall prepare also:
415 x 465 mm (16.5 in. x 18.5 in.) plywood board 20 mm (7/8 in.) thick
Wood screws
Screws to fasten the G350 to the wall
You might also need wire cutters to attach the grounding conductors, if your site uses a ground block.