Troubleshooting

If you experience difficulties operating your AUTODOME camera, refer to the following. If the
guidelines do not enable you to solve the problem, contact an authorized technician.
Problem
Need to remove trim
ring.
Nothing appears on the
screen.
The image on the
screen is dim.
The contrast on the
screen is too weak.
The image on the
screen is flickers.
The image on the
screen is distorted.
No video
No camera control
Camera moves when
moving other cameras
2014.04 | 2.0 | F.01U.283.679
Questions to Ask/Actions to Resolve the Problem
Use a slotted screw driver and push the clips outward while gently pulling down
on the edge of the trim ring.
Are the power cord and line connection between the camera and monitor made
properly?
Is the lens dirty? If so, clean the lens with a soft, clean cloth.
Adjust the contrast feature of the monitor. Is the camera exposed to strong light?
If so, change the camera position.
Does the camera face directly into the sun or fluorescent lighting? If so,
reposition camera.
Is the power frequency set properly in sync? If the power frequency is not set
correctly, the line lock synchronization mode cannot be used. Set the
synchronization mode to INT.NTSC Model power frequency in LL mode: 60 Hz.
Check that the mains power to the power supply is on.
Check to see if you have a web page.
If you do not, then you may have the wrong IP address. Use Configuration
Manager to identify the correct IP address.
If O.K., then:
Check that there is 24 V output from the transformer.
If O.K., then:
Check the integrity of all wires and mating connectors to the camera.
Ensure that the LAN cable has good connection and is secured.
Refresh the browser and ensure that video is updated.
For analog cameras: Cycle the camera's power off and on.
For IP cameras: Ping the camera's IP address and try again to control the
camera.
Check that the camera's IP address is properly set.
If camera's IP address is not set, then:
Use Configuration Manager to confirm that two cameras do not have the
same IP address. If they do, change the address of one of the cameras.