en | Configuration via IP, Advanced Mode
Caution!
When a cellphone is used as the receiver, make sure to activate the e-mail or SMS function,
!
depending on the format, so that these messages can be received.
You can obtain information on operating your cellphone from your cellphone provider.
Image size
Select the appropriate image size: Small, Medium, Large, 720p, 1080p.
Attach JPEG from camera
Click the checkbox to specify that JPEG images are sent from the camera. An enabled video
input is indicated by a check mark.
Destination address
Enter the e-mail address for alarm e-mails here. The maximum address length is 49 characters.
Sender address
Enter a unique name for the e-mail sender, for example the location of the device. This will
make it easier to identify the origin of the e-mail.
Note: The name must include at least two character groups separated by a blank (for example,
Parking Garage) in order for the system to generate an email from that name, as in "From
Parking Garage". Text with only one group of characters (for example, Lobby) will not
generate an email.
Test e-mail
You can test the e-mail function by clicking the Send Now button. An alarm e-mail is
immediately created and sent.
14.36

Alarm Task Editor

Caution!
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
!
procedure cannot be reversed.
In order to edit this page, you must have programming knowledge and be familiar with the
information in the Alarm Task Script Language document.
As an alternative to the alarm settings on the various alarm pages, you can enter your desired
alarm functions in script form here. This will overwrite all settings and entries on the other
alarm pages.
1.
2.
3.
14.37
Alarm Rules
The camera features an alarm rule engine. In its simplest form, an alarm rule can define which
input(s) activate which output(s). Basically, an alarm rule allows you to customize the camera
to respond automatically to different alarm inputs.
To configure an alarm rule specify one input from a physical connection, a motion detection
trigger, or from a connection to the camera's LIVE page. The physical input connection can be
activated by dry contact devices such as pressure pads, door contacts, and similar devices.
2014.04 | 2.0 | F.01U.283.679
Click the Examples link under the Alarm Task Editor field to see some script examples. A
new window will open.
Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your
requirements.
When you are finished, click the Set button to transmit the scripts to the unit. If the
transfer was successful, the message Script successfully parsed is displayed over the
text field. If it was not successful, an error message will be displayed with further
information.