The inside of the housing may contain packing material to safeguard the camera during
shipping. If so, you must remove the packing material before attaching the in-ceiling housing
to the interface box.
Notice!
To avoid excessive moisture saturation inside the housing, limit the amount of time that the
bubble is disconnected from the housing. Bosch recommends that the bubble be removed
from the housing for no more than five (5) minutes.
Remove the bubble from an in-ceiling housing
1.
2.
Figure 11.1: Bubble Release Screw
3.
Remove the bubble from a pendant housing
1.
2.
2014.04 | 2.0 | F.01U.283.679
Loosen the lockscrew (item 1 in the illustration below) in the trim ring using a P1 or
smaller Phillips screwdriver until the bubble can rotate freely.
Then rotate the bubble counterclockwise approximately 1/4 turn until it releases from the
In-Ceiling Housing. See the figure below for an illustration.
Remove the foam inserts surrounding the camera module.
Using both hands, apply a firm counterclockwise (looking up at the dome) rotational
force on the Pendant Bubble Assembly to set the bubble latch.
Insert a small (2 mm) straight blade screw driver into the release opening in the bubble
trim-ring to release the lock, and then remove the screwdriver.