Installation note:
Clean the contact surface where you removed the sensor retaining plate, or where you need to install the
1.
new one.
Guide the latches that hold the sensor in the bracket into place.
2.
Squeeze the latches together until they latch to the metal frame.
3.
4.
Remove the backing from the new plate, and place the plate on the surface between the sensor mounting
legs.
Reconnect the cable, and reroute the cable through the retainer.
5.
Bin-full/narrow media sensor flag and exit deflector removal
The bin-full/narrow media sensor flag and the exit deflector are in the same FRU. See
full/narrow media sensor flag removal" on page
4-30.
5025-2xx, 4xx
"Exit deflector and bin-
Repair information