Toshiba MMU-AP0091H Installation Manual page 92

Super modular multi outdoor / indoor unit air conditioners
Hide thumbs Also See for MMU-AP0091H:
Table of Contents

Advertisement

n Single outdoor unit
Voltage
Heat Pump
Nominal
Range
Model
Voltage
MMY-
(V-Ph-Hz)
Min
Max
MAP0501HT7
380-3-60
342
418
MAP0601HT7
380-3-60
342
418
MAP0801HT7
380-3-60
342
418
MAP1001HT7
380-3-60
342
418
MAP1201HT7
380-3-60
342
418 10.0 + 10.0
n Combination of outdoor unit
Voltage
Heat Pump
Nominal
Range
Model
Voltage
MMY-
(V-Ph-Hz)
Min
Max
AP1401HT7
380-3-60
342
418
AP1601HT7
380-3-60
342
418
AP1801HT7
380-3-60
342
418
AP2001HT7
380-3-60
342
418
AP2201HT7
380-3-60
342
418
AP2211HT7
380-3-60
342
418 10.0 + 10.0
AP2401HT7
380-3-60
342
418
AP2411HT7
380-3-60
342
418 10.0 + 10.0
AP2601HT7
380-3-60
342
418
AP2801HT7
380-3-60
342
418
AP3001HT7
380-3-60
342
418
AP3201HT7
380-3-60
342
418
AP3211HT7
380-3-60
342
418 10.0 + 10.0
AP3401HT7
380-3-60
342
418
AP3411HT7
380-3-60
342
418 10.0 + 10.0
AP3601HT7
380-3-60
342
418
AP3611HT7
380-3-60
342
418 10.0 + 10.0
AP3801HT7
380-3-60
342
418
AP4001HT7
380-3-60
342
418
AP4201HT7
380-3-60
342
418 10.0 + 10.0
AP4401HT7
380-3-60
342
418 10.0 + 10.0
AP4601HT7
380-3-60
342
418 10.0 + 10.0
AP4801HT7
380-3-60
342
418 10.0 + 10.0
Legend
MCA
: Minimum Circuit Amps
MOCP
: Maximum Overcurrent Protection (Amps)
ICF
: Maximum Instantaneous Current Flow Start
RLA
: Rated Load Amps
Compressor
RLA
LRA
4.2 + 4.2
4.8 + 4.8
5.4 + 5.4
6.9 + 6.9
Compressor
Unit No.1
Unit No.2
RLA
LRA
RLA
LRA
5.4 + 5.4
4.8 + 4.8
5.4 + 5.2
5.4 + 5.4
6.9 + 6.9
5.4 + 5.4
6.9 + 6.9
6.9 + 6.9
5.4 + 5.4
5.4 + 5.4
6.9 + 6.9
5.4 + 5.4
5.4 + 5.4
10.0 + 10.0
6.9 + 6.9
5.4 + 5.4
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
5.4 + 5.4
5.4 + 5.4
6.9 + 6.9
6.9 + 6.9
5.4 + 5.4
10.0 + 10.0
6.9 + 6.9
6.9 + 6.9
10.0 + 10.0
10.0 + 10.0
6.9 + 6.9
6.9 + 9.9
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
10.0 + 10.0
10.0 + 10.0
10.0 + 10.0
10.0 + 10.0
10.0 + 10.0
LRA
: Locked Rotor Amps
FLA
: Full Load Amps
kW
: Fan Motor Rated Output (kW)
Unit No.3
Unit No.4
RLA
LRA
RLA
LRA
4.8 + 4.8
5.4 + 5.4
5.4 + 5.4
5.4 + 5.4
6.9 + 6.9
5.4 + 5.4
5.4 + 5.4
6.9 + 6.9
5.4 + 5.4
5.4 + 5.4
6.9 + 6.9
5.4 + 5.4
5.4 + 5.4
6.9 + 6.9
5.4 + 5.4
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
6.9 + 6.9
10.0 + 10.0
Fan Motor
Power Supply
kW
FLA
MCA MOCP
0.60
0.8
16.5
0.60
0.8
16.5
0.60
1.0
20.0
0.60
1.1
22.5
0.60
1.1
24.5
Fan Motor
Power Supply
kW
FLA
MCA MOCP
0.6 × 2
1.0 + 0.8
36.5
0.6 × 2
1.0 + 1.0
40.0
0.6 × 2
1.0 + 1.1
42.5
0.6 × 2
1.1 + 1.1
45.0
0.6 × 3
1.0 + 1.0 + 0.8
56.5
0.6 × 2
1.1 + 1.1
47.0
0.6 × 3
1.0 + 1.0 + 1.0
60.0
0.6 × 2
1.1 + 1.1
49.0
0.6 × 3
1.1 + 1.1 + 1.0
62.5
0.6 × 3
1.1 + 1.1 + 1.0
65.0
0.6 × 3
1.1 + 1.1 + 1.1
67.5
0.6 × 4
1.0 + 1.0 + 1.0 + 1.0
80.0
0.6 × 3
1.1 + 1.1 + 1.1
69.5
0.6 × 4
1.1 + 1.0 + 1.0 + 1.0
82.5
0.6 × 3
1.1 + 1.1 + 1.1
71.5
0.6 × 4
1.1 + 1.1 + 1.0 + 1.0
85.0
0.6 × 3
1.1 + 1.1 + 1.1
73.5
0.6 × 4
1.1 + 1.1 + 1.1 + 1.0
87.5
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
90.0
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
92.0
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
94.0
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
96.0
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
98.0
NOTE :
RLA is based on the following conditions.
Indoor temperature
: 27°C DB/19°C WB
Outdoor temperature : 35°C DB
60Hz
ICF
20
20
30
30
30
ICF
40
50
50
60
70
60
70
60
70
80
80
90
80
100
80
100
90
100
100
110
110
110
110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents