2.1.2 Standard Calibration

During the Standard Calibration process, the printhead assembly can be raised for visual access to the
media and media sensor. In addition, displayed sensor readings can be used to indicate the best position
over the media. These features are helpful when using small, position-critical TOF notches or marks.
Three readings are required:
Empty: No media in the sensor.
Gap (or Mark): Only the backing, notch, or reflective mark in the sensor.
Paper: The label (with the liner attached) in the sensor.
Make sure media is loaded and that the appropriate Sensor Type has been selected, then perform the
Standard Calibration as follows:
Step
Action
Turn 'On' the printer.
1
2
Press the
Key.
Raise the printhead
assembly.
3
Press the
enter the Media Settings
menu.
4
Press the
scroll to 'SENSOR
CALIBRATION'.
5
Press the
6
Press the
Remove the media from the
Media Sensor then press
any key.
Adjustments and Maintenance
Displayed Message



Key to


Key and


Key.


Key.


Wait for the printer to initialize
(about six seconds) before
proceeding.
You are entering Menu Mode.
See the Operator's Manual for
menu layout details.
Press the
procedure.
You are beginning the standard
calibration procedure.
This sets the parameter for the
'empty' value.
Where 'yyy' is a numerical value
representing the current sensor
reading.
2-2
Comment
Key to abort this