Datamax W-Class Maintenance Manual page 96

Table of Contents

Advertisement

Replacement:
1. If removed, ensure the nylon Washer is on the Media Sensor Shaft; then slide the shaft through the
Side Plate, approximately one inch into the printer.
2. First, slide the Long Spacer and then the Short Spacer onto the Media Sensor Shaft.
3. Thread the Media Sensor Shaft through the Media Sensor Housing.
4. On the media side of the printer, slide the Short Spacer toward the inner wall and the Long Spacer
toward the Side Plate; then install two E-Clips onto the Media Sensor Shaft.
5. On the electronics side of the printer, install the E-clip onto the shaft, connect the Media Sensor to J9
on the backplane board, dress the wiring and install the Cable Clamp.
6. Replace the covers; see Section 4.1.
7. Plug in and turn 'On' the printer. Calibrate the 'empty' sensor value by simultaneously pressing and
holding (about four seconds) the
Removal and Replacement
and
4-26
Keys.