Removal and Replacement

4.4 Drive Motor

Removal:
1. Turn 'Off' and unplug the printer.
2. Remove the Electronics Cover; see Section 4.1.
3. Unplug the Drive Motor harness from connector J6 of the power supply board.
4. Loosen the two screws on the Upper Belt Tensioner then unhook and remove the Tensioner Spring.
5. Remove the Lower Belt Tensioner Screw then unhook and remove the Tensioner Spring.