Battery Installation
5.Re-attach the harness to the Battery posts with
an open end wrench as shown in (fi gure 7.2.1). It
is recommended to tighten the Battery Harness
hardware to a maximum torque of 60in-lbs
6. It is important to follow the basic hardware
stackups
shown
below
the harness to the battery posts for a reliable
connection.
Option 1 Post on top
Std washer
Bolt
Lock washer
7. Lift the batteries into the battery box and
reconnect the Batteries to each other as shown in
(fi gure 7.2.5). Then reconnect the Battery harness
to the power base. (A) (fi gure 7.2.6)
Batteries installed incorrectly can blow the fuse for this system. Pay careful attention to install
the battery harness across both batteries instead of to each of the batteries individually. Refer
to Battery Wiring Diagram in Section 2 for reference.
PAGE 7.2
JANUARY 2012
Section 7
when
re-attaching
Option 2 Post on top
Nut
QM-7 SERIES SERVICE MANUAL
fig. 7.2.1
Option 3 Flat top
fig. 7.2.5
A
fig. 7.2.6
SUNRISE MEDICAL