PHYSICAL CHARACTERISTICS

RedNet 1's dimensions are shown in the diagram below:
247.5mm / 9.74"
RedNet 1 requires 2U of vertical rackspace and at least 350 mm of rack depth, to allow for cables.
RedNet 1 weighs 4.12 kg and for installations in a fixed environment (e.g., a studio), the front panel
mounting screws will provide adequate support. If the units are to be used in a mobile situation
(e.g., flight-cased for touring, etc.), consideration should be given to using side support rails within
the rack.
RedNet 1 generates no significant heat, and is normally cooled by natural convection, though an
internal cooling fan is fitted. We recommend that the unit should not be used in locations where
the ambient temperature is greater than 30°C(85°F). However, if this is unavoidable, the fan can be
turned on and off from RedNet Control.
Ventilation is via slots in the enclosure at both sides. Do not mount RedNet 1 immediately above any
other equipment which generates significant heat, for example, a power amplifier. Also, ensure that
when mounted in a rack, the side vents are not obstructed.

POWER REQUIREMENTS

RedNet 1 is mains-powered. It incorporates a 'Universal' power supply, which can operate on any AC
mains voltage from 100 V to 240 V. The AC connection is made via a standard 3-pin IEC connector on
the rear panel. A mating IEC cable is supplied with the unit, which should be terminated with a mains
plug of the correct type for your country.
The AC power consumption of the RedNet 1 is 45 VA.
Please note that there are no fuses in RedNet 1, or other user-replaceable components of
any type. Please refer all servicing issues to the Customer Support Team (see "Customer
Support and Unit Servicing" on page 55).