Performance Specifications - Focusrite RedNet Installation Manual

Hide thumbs Also See for RedNet:
Table of Contents

Advertisement

PERFORMANCE SPECIFICATIONS

Word Clock
Connectors
Output
Input
MADI Coaxial
Electrical standard
Recommended Cable
Connector
MADI Optical
Optical Standard
Recommended Cable
Connector
SRC
SRC lock range
Sample Rate Ratio Limit
THD
Latency
Channel Count
MADI Clock
Single
Single Varispeed
Double
Double Varispeed
Quad
Quad Varispeed
Power
PSU
BNC 75Ω
5V 75Ω DC-coupled
locks down to 0.2V AC-coupled (75Ω software switchable termination)
as per AES10:2008
75Ω characteristic impedance
BNC 75Ω
as per AES10:2008 (ISO/IEC 9314-3, FDDI, ANSI X3.166)
Multi-mode, Graded-index, 62.5µm core, 125µm cladding
Duplex-SC
41kHz to 216kHz (MADI)
6:1
-130dB typical
43 to 196 samples (Network and MADI sample rate dependent)
RedNet Clock
Single
Double
64
32
56
32
32
32
28
28
16
16
14
14
Internal, Universal type, consumption 30VA
Quad
16
16
16
16
16
14
48

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rednet 2

Table of Contents