9.0 Annual Servicing

9.1
IMPORTANT: It is possible that some soot
may be deposited on the coals after use. This
is acceptable providing it is not allowed to
accumulate.
CAUTION: The coals are extremely fragile
and must be handled accordingly. Gloves
should be worn and any inhalation of the dust
should be avoided. Keep the coals away from
children at all times. Never use coals other
than those originally supplied or Genuine Baxi
Spare Parts. Never put additional coals on the
fire. Please read section 1.3 Important
Information.
1. For reasons of safety and economy it is
important to service the fire and boiler annually.
9.2
WARNING: Isolate the gas and electricity
supplies to the boiler and fire unit before
servicing.
1. In order to service the boiler unit, the fire must
be disconnected and removed. Remove the fire
as follows-
2. Lift the controls access door away from the
fender assembly (Fig. 38).
OFF Position
3. Turn off the gas supply at the service cock
(Fig. 40).
4. Carefully remove all the loose coals, side
cheeks, rear and front coals (Fig. 41).
5. Remove the glass retaining assembly
(Fig. 43).
6. Carefully remove the three amber glass pieces
(Fig. 44).
7. Lift the fender assembly to disengage it from
the hooks and remove it (Fig. 45).
8. Disconnect the gas supply to the fire at the
gas service cock connection (Fig. 39).
9. Remove the two screws retaining the sides of
the fire combustion box to the fire base tray
(Fig. 42).
Annual Servicing
Preparation