Boiler Hood
Flue
Spigot
Fig. 46
Control Box
Fig. 47
Burner
Retaining
Fig. 49
Screw
Injector
Fig. 50
2.5 - 4mm
Pilot/A.S.D.
Fig. 51
Assembly
Fig. 48
Pilot Aeration Hole
9.0 Annual Servicing
9.2
Preparation (Cont)
8. Slacken the two screws inside the flue spigot
(Fig. 46).
9. Disconnect the electrical plug from the socket
attached to the control box (Fig. 47).
10. Slide the fire combustion box forward to
disengage it from the flue spigot and lift away
(Fig. 48) taking care not to snag any electrical
wiring.
9.3
Cleaning the Burner & Injectors
1. Undo the screw holding the burner to the
controls mounting plate, and disengage the
burner inlet from the injector (Fig. 49).
2. Using a soft brush, remove any dirt from the
burner and ensure that the ports are free from
obstruction (Fig. 49).
3. Using a spanner on both the adaptor barrel
and fire injector, remove the injector from the
barrel (Fig. 50).
4. Examine and clean the injector. Do not use
any hard tools such as pins or wire. Refit the
injector (Fig. 50).
9.4
Cleaning the Pilot/A.S.D. Assembly
(Fig. 51)
NOTE: No attempt should be made to clean
the device using any hard tools, including
pins or wire.
WARNING: The pilot/A.S.D. assembly must
not be adjusted in any way.
1. The A.S.D. must not be altered so that it will
not operate or be bypassed in any way.
2. Ensure that the pilot burner aeration hole is
free from lint, debris etc.
3. If necessary clean the electrode and target,
and check that the spark gap is 2.5 - 4.0mm.
4. The thermocouple cannot be changed as an
individual component. The complete assembly
must be replaced in the event of one or other
component failure(s).
5. Only use a Genuine Baxi Spare Part.