Baxi TS Super Installation And Servicing Instructions page 22

Bermuda inset 3 super fireside gas central heating units
Table of Contents

Advertisement

Boiler Hood
Flue
Spigot
Fig. 65
Control Box
Fig. 66
Fig. 67
Burner
Retaining
Fig. 68
Screw
Injector
Fig. 69
22
Fig. 64
Base Tray Securing Screw
10.0
Changing Components
10.1
Changing Components (continued)
9. Remove the two screws retaining the sides of
the fire combustion box to the fire base tray
(Fig. 67).
10. Remove the two screws inside the flue spigot
(Fig. 65).
11. Disconnect the electrical plug from the socket
(Fig. 66).
12. Slide the fire combustion box forward to
disengage it from the flue spigot and lift away
(Fig. 64) taking care not to snag any electrical
wiring.
NOTE: After changing any components carry
out checks for gas soundness.
10.2
Burner and Injector
1. Undo the screw holding the burner to the
controls mounting plate, and disengage the
burner inlet from the injector (Fig. 68).
2. Fit the new burner in reverse order.
To change the injector remove the burner as
described above.
3. Using a spanner on both the adaptor barrel
and fire injector, remove the injector from the
barrel (Fig. 69).
4. Fit the new injector.