Commissioning The Fire - Baxi TS Super Installation And Servicing Instructions

Bermuda inset 3 super fireside gas central heating units
Table of Contents

Advertisement

Pressure Test Point
Sealing Screw
Fig. 22
Green Power
ON Indicator
ON/OFF
Button
Green
High Setting
Indicator
HIGH/LOW
Button
Green
Illumination
ON Indicator
Illumination
Button
Controls & Bezel
Fig. 24
Gas Service Cock
Fig. 23
Fire and Boiler
ON Position

6.0 Commissioning the Fire

6.1
Commissioning the Fire
1. Turn on the main gas and electrical supply and
press the
button (Fig. 24) to check that the
illumination effect operates.
2. Turn the gas service cock to the fire and boiler
on position as shown, then purge according to in
GB BS 6891 and in IE the current edition of I.S.
813 "Domestic Gas Installations". (Fig. 23).
3. Check for gas soundness from the gas service
cock to the fire inlet connection.
4. Release the pressure test point sealing screw
from the injector adaptor and connect a pressure
gauge (Fig. 22).
5. The fire has three settings:-
OFF
LOW
6. The ON button has a safety feature built in. It
should be pressed and held for 3-4 seconds.
(The green power ON indicator comes on when
the ON/OFF button is pressed (Fig. 24).)
7. During the ignition sequence you will hear an
audible signal. This lasts for up to 20 seconds.
The fire will then automatically ignite on the low
setting.
NOTE: If the ON/OFF button is pressed and
held for less than 3 seconds the fire will not
ignite. This is a built in safety feature.
8. If the fire fails to ignite or goes out at any time,
switch the fire off by pressing the ON/OFF button
once and repeat the procedure (Fig. 24).
9. Turn the fire to high setting by pressing the
HIGH/LOW button. The green high setting
indicator will come on to confirm this (Fig. 24).
This operation can be undertaken during the
ignition sequence.
10. Check the fire gas pressure.
The pressure should be 9.0 mbar (3.6 in wg). If
the pressure is not correct, check that all gas
cocks are fully open and that the meter pressure
is correct. No adjustment to the setting pressure
is possible.
11. Pressing the ON/OFF button once will turn
the fire off. The green power ON indicator will go
out to confirm this (Fig. 24). Disconnect the
pressure gauge and replace the pressure test
point sealing screw, ensuring a gas tight seal
(Fig. 22).