Factory Default Settings; Battery Temperature Sensor - Monaco 2009 Knight Owner's Manual

Table of Contents

Advertisement

shore setting aC Power
50 amp
when hooked to 50 amp shore service.
30 amp
when hooked to 30 amp shore service.
20 amp
when hooked to 20 amp shore service.
used when shore service is severely limited or
10 amp
experiencing shore power overload.
Minimum charge capacity setting. used when shore
5 amp
service is severely limited or experiencing shore
power overload.
Inverter three-stage charging cycle:
Bulk Charge Cycle: Brings the DC
voltage up high, initially between 14.2
- 14.6 Volts DC. The length of time the
inverter is in Bulk Charge depends on
the state of charge of the batteries.
Absorb Cycle: Absorb Cycle battery
voltage is the same as the Bulk Charge
Cycle, between 14.2 - 14.6 Volts DC.
Length of the Absorb Cycle is a timed
event determined by the inverter.
Float Charge Cycle: Charge voltage is
generally around 13.3 - 13.7 Volts DC.
Approximately 80% of the charging
cycle has been completed by this time.
INFORMATION
Refer to the invertor OEM manual
located in the Owner's Information
File Box for detailed instructions.
Bulk charge
water (charger) on full
until bucket (battery) is
80% full.
absorb charge
water (charger) slows until
bucket (battery) is 90%
full.
float charge
water (charger) slowly
trickles into bucket
(battery) until 100% full.
Water (charger) will adjust
flow to maintain level.
Hose = Inverter in Charge Mode
Bucket = Battery

Factory Default Settings

NOTE
The inverter will charge the batteries
with AC power applied regardless of
remote status.
functon
search
low Battery Cutoff
Battery Bank
Battery Type
Charge rate
Contrast

Battery Temperature Sensor

A Battery Temperature Sensor (BTS) is
affixed to one of the house battery terminals
to measure battery temperature and send that
information to the inverter. When battery
temperature rises, the inverter will decrease
charge voltage to prevent boiling the batteries.
When battery temperature cools, the inverter
will raise charge voltage. Voltage compensation
with temperature variation is necessary to
keep charge voltage at optimum values. If the
BTS cord is unplugged from the inverter, the
inverter will use a temperature default setting
of 77º F/25º C as a reference point.
06023b
default
5 watts
11 volts DC
400 ah
Liquid Lead Acid
80 %
75 %
1

Advertisement

Table of Contents
loading

Table of Contents