Panasonic M2X Series Instruction Manual page 64

For 3-phase induction motor speed control
Table of Contents

Advertisement

Detailed Parameter Description
⑫ Write
Holding
parameter
press
into
DATA SET
inverter
for 1 second.
⑬ Wait for
approx. 10
seconds
Parameter
values have
been written
from the
operation
panel into the
inverter
circuits
Simultaneously press
△ and
Return to
▽ to cancel trip.
monitor mode
To copy parameter values to two or more inverters, use the master panel produced in [1] and repeat the
steps of [2].
∗ If parameters are not copied correctly,
self-diagnosis trip.
To cancel the display, press STOP . For corrective action, refer to the description that follows.
Error message
Parameter values to be copied are invalid.
The copy is attempted between inverters of
different series.
After panel initialization, attempt is made to
write parameter value from the operation
panel into the inverter without first reading
parameter values in inverter out to the panel.
STOP
,
Description
-
-
64
• 2-digit and 5-digit LEDs flash.
approx. 3 seconds.
• Self-diagnosis trip occurs.
• Monitor mode
or
is displayed followed by no
Corrective action
The parameter values may have
been destroyed by external noises.
Press STOP and repeat steps
starting with <1. Initializing
operation panel>.
Be sure to copy between the same
series.
Press STOP and repeat steps
starting with <1. Initializing
operation panel>.
is displayed for