For 3-phase induction motor speed control
Table of Contents

Advertisement

Operation Function
< 16-speed mode >
I I I I 3
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
• "ON" and "OFF" indicate the connection between each frequency setting
selection terminal and the "G" terminal.
Control terminal number
I I I I 4
I I I I 5
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
- 30 -
Frequency setting
I I I I 6
0th speed frequency
OFF
1st speed frequency
OFF
2nd speed frequency
OFF
3rd speed frequency
OFF
4th speed frequency
OFF
5th speed frequency
OFF
6th speed frequency
OFF
7th speed frequency
OFF
8th speed frequency
ON
9th speed frequency
ON
10th speed frequency
ON
11th speed frequency
ON
12th speed frequency
ON
13th speed frequency
ON
14th speed frequency
ON
15th speed frequency
ON