Specifications - Panasonic M2X Series Instruction Manual

For 3-phase induction motor speed control
Table of Contents

Advertisement

Specifications

(1) 3-phase power supply specifications
Model
Applicable motor (kW)
Output capacity (kVA)
Rated output current (A)
Rated output voltage
Voltage
Frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
Control method
Output frequency range
Frequency setting accuracy
Frequency setting resolution
Frequency setting signal
Voltage/frequency characteristic
Overload current rating
Regenerative brake torque
DC brake
Acceleration/deceleration time
Jogging frequency range
Operation mode
Others
Protective functions
Protective structure
Cooling method
Weight (kg)
∗1 The applicable motors indicate the 3-phase (4-pole) induction motors manufactured by Motor
Company, Matsushita Electric Industrial Co., Ltd.
To use other manufacturer's motor, select a proper motor within the inverter's rating.
∗2 The output capacity indicates the capacity under a rated output voltage of 460 V.
∗3 The output voltage shall not exceed the power supply voltage.
M2X044*** M2X084*** M2X154*** M2X224*** M2X374*** M2X554*** M2X754***
∗ 1
0.4
0.75
∗ 2
1.3
2.0
1.5
2.5
∗ 3
0.5 - 400Hz (Start/stop at 0.5Hz)
Digital: 0.01 Hz
Analog: Set frequency range/1000 Hz (0.05 Hz min.)
0 to +5VDC, 0 to +10V, 4 to 20mA
150% or more
(for short time)
Brake starting frequency, brake time and brake intensity are adjustable.
(0 to 3 sec: 0.01 sec. step, 3 to 10 sec.: 0.1 sec. step, 10 sec. or more: 1 sec. step)
* Time required for change by 50 Hz. Up to four types of acceleration/deceleration time can be specified.
2-speed mode, 4-speed mode, 8-speed mode, 16-speed mode
Automatic boost / Slip frequency vector control can be selected.
Automatic voltage adjustment function / Retry function can be selected.
PID function, RS-485 communication function (only for the inverter with
communication interface), Parameter lock function are available.
Undervoltage protection, Overcurrent protection, Overvoltage protection,
Instantaneous power failure protection, Stall prevention, Overload limit (current
limiter), Overload trip (electronic thermal trip), Restart prevention upon power
recovery, Self-diagnosis trip (Causes of trip can be stored for up to five events in the
IP40 (Fully enclosed) (With ventilation cover)
Natural cooling
2.1
-
67
1.5
2.2
3.0
4.4
3.7
5.5
3-phase 380 - 460VAC
3-phase 380 - 460VAC
50/60Hz
-15%,+10%
±5%
Low noise sine wave PWM
±0.5%(25℃±10℃)
Base frequency: 30 to 400 Hz (1 Hz step)
Reduced torque pattern is available.
150% for one minute
0 to 3600 sec.
0 - 30Hz
past.)
Forced air cooling
2.2
-
3.7
5.5
7.5
7.2
10.4
12.8
9.0
13
16
50% or more
(for short time)
4.0