Operation Function

Selection of the run command

The M2X series inverter provides the following six types of operations depending on
whether frequency commands and run commands are entered through the operation panel
or the terminal block.
Speed command
From
Terminal block
operation
FIN1 or FIN2 on
panel, or
terminal block
control dial
Default settings of [
Frequency command selection] and [
, respectively.
Frequency command selection changing procedure
Example) Change [
Step
① Power ON
② Parameter
Press DATA SET
number mode
Using
parameter No.
Press DATA SET
③ Parameter set
value mode
Using
parameter value
Press DATA SET to
save the value
∗1 The run command from the terminal block overrides the command from the operation panel, if both
are enabled.
The RUN switch on the operation panel is active only when both the CCW/stop switch (I1) and the
CW/stop switch (I2) on the terminal block are OFF. If both or one of [I1] and [I2] are turned on while
the RUN switch is active, the operation mode set from RUN switch is cancelled.
∗2 The "FIN1" and "FIN2" terminals are intended for voltage command (0 to 5 VDC or 0 to 10 VDC) and
current command (4 to 20 mADC), respectively. For details, refer to "Terminal function: "(2) Control
Terminal" on P18.
Run command
Operation
Terminal
panel
∗2
∗1
∗1
Frequency command selection] from
Switch
, select the
, select the
- 24 -
Frequency command
block
selection
∗1
or
∗1
or
or
or
or
or
Run command selection] are
to
Operation panel
LED display
Parameter
Run command
selection
(both)
(both)
(panel)
(panel)
(terminal block)
(terminal block)
.
and