Operation Function

Run mode

The inverter operates in the following two run modes.
Select the desired mode in the parameter [
Mode
I I I I 1 I I I I 2
2-speed
CCW
CW
4-speed
CCW
CW
8-speed
CCW
CW
16-speed
CCW
CW
In the 4-, 8- or 16-speed mode, the following multi-speed operation is enabled by short-circuiting or
opening the frequency setting selection terminals. When all the terminals are opened, the 0th speed
frequency is selected, allowing you to specify frequency with the [
parameter, external frequency setting control dial, or the inverter's control dial.
With [
Frequency command selection], select whether to use the 0th speed frequency, external
frequency setting control dial or the inverter's control dial.
■ Input terminal description
(1) Input terminals are given the following priority.
DC brake < Normal operation < Jogging < Free-run stop < External forced trip
Example)
① If the run command is issued while the DC brake is activated, the motor
will immediately start running.
② If the free-run stop command is issued during jogging operation, the
motor will coast to stop.
③ Even if the run command is issued while the free-run command is
activated, the motor will not start running.
(2) If both the CCW and CW commands are issued during trip, the trip can be
canceled. Before canceling the trip, remove the cause of the trip.
∗1 [
I5 function selection], [
Function of terminal block
I I I I 3
I I I I 4
Free-run stop
External forced trip
command
CCW
CW
No.2 acceleration/
jogging
jogging
deceleration time
selection
Trip reset command
Free-run stop
External forced trip
command
Frequency setting
No.2 acceleration/
selection
deceleration time
selection
Trip reset command
Frequency setting selection
Frequency setting selection
I6 function selection]
- 28 -
Run mode selection].
∗1
I I I I 5
I I I I 6
Free-run stop
External forced trip
command
No.2 acceleration/
deceleration time
selection
Trip reset command
Free-run stop
External forced trip
command
No.2 acceleration/
deceleration time
selection
Trip reset command
Free-run stop
External forced trip
command
No.2 acceleration/
deceleration time
selection
Trip reset command
Set frequency (0th speed)]
Setting
in
[
Run
∗1
mode
selection].
[Default setting]