Function Of Each Mode - Panasonic VF0 Series Instruction Manual

Compact inverter 400v class
Hide thumbs Also See for VF0 Series:
Table of Contents

Advertisement

The VF0 has the following four modes.
(1) Output frequency, current display mode, (2) Frequency setting, monitor
mode, (3) Rotation direction setting mode, (4) Function setting mode
Normally, use in the output frequency, current display mode.
This mode is entered when the power is turned ON.
(1) Output frequency, current display mode
[Output frequency display]
1. Output
(2) Frequency setting, monitor mode
The frequency can be digitally set, and the
parameter P09 frequency command can
be monitored
(3) Rotation direction setting mode
The rotation direction can be set
and the control status (local/
external) can be monitored with
panel operations.
[Mode display]
(4) Function setting mode
The parameter data can be changed and
monitored in this mode.
The parameter No. is displayed when this mode
is entered.
Set the required No. with the
A password can be set in this mode.
Downloaded from
www.Manualslib.com

Function of Each Mode

2.
Operation
frequency
preparation
(line speed)
completed display
5
0.
0
0
0
0
MODE
F
[Mode display]
MODE
d
r
MODE
[Parameter No. display]
[Password display]
MODE
manuals search engine
SET
3. 0V stop
display
SET
0.
0
SET
MODE
r
[Data change]
Change the data with the
·
SET
and press the SET button to set the data.
L
MODE
Local –
Forward run
Note) When parameter P08 is set to "1" just with
SET
SET
and
buttons.
P
0
1
MODE
P
S
Output current display mode
The output current of the inverter is
displayed.
0.
0
SET
[Data change and monitor]
Change the frequency with the
·
and
buttons, and press the SET
button to set the data.
The parameter P09 command
·
frequency is displayed except
during the digital setting.
SET
and
During external
F
L
r
control, L will
Local –
change to E.
Reverse run
the monitor, the settings cannot be changed.
[Data change]
The data can be changed with the
and
buttons.
Press the SET button, and set the
changed data. (The next parameter
No. will appear when the SET button
is pressed.)
The current parameter No. will
appear when the MODE button is
pressed.
(The data is not set.)
A
buttons,
30

Advertisement

Table of Contents
loading