System Control - Abus WIRELESS ALARM SYSTEM Installation Instructions Manual

Wireless alarm system
Hide thumbs Also See for WIRELESS ALARM SYSTEM:
Table of Contents

Advertisement

1 1
2 2
7.2.2

System Control

Under System Control, you make settings that control specific functions of the complete system.
NOTE:
Under this menu item, it is important that you press the lozenge button
exit the menu by pressing
To access the System Control menu option:
1.
Select the main menu System as described on page 7-23.
2. In the System menu, press
3.
Select and configure the settings in the System Control menu as follows:
System Control:
Quick-Key
1 1
2 2
01
01
1 1
2 2
02
02
1 1
2 2
03
03
1 1
2 2
04
04
1 1
2 2
05
05
, your settings are lost.
2 2
to get to System Control. You see the following on the display:
Parameter
Quick arm
YES:
No user PIN is necessary for activating the system or an area.
NO:
A user PIN is necessary for activating the system or an area. Choose this setting if
the alarm system or an operating panel is accessible to the public or to children.
Quick UO
YES:
A user can activate a switch output without a user PIN.
NO:
A user PIN is necessary to activate a switch output.
Allow Bypass
YES:
A zone can be omitted (excluded from surveillance) by an authorised user.
NO:
Omitting zones from surveillance is not possible.
Quick Bypass
YES:
No user PIN is required for omitting a zone.
NO:
A user PIN is required for omitting a zone.
False Code Trouble
YES:
If an incorrect user PIN is entered three times, the operating panel is locked and, if
programmed, an alarm is sent by telephone. Bad PIN input is displayed as a fault on
the operating panel.
NO:
If an incorrect user PIN is entered three times, the operating panel is locked and a
local alarm is sounded.
before exiting so that your data is saved. If you
Default
YES
YES
YES
NO
YES
Range
YES/NO
YES/NO
YES/NO
YES/NO
YES/NO
7-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fu9010