Abus WIRELESS ALARM SYSTEM Installation Instructions Manual page 43

Wireless alarm system
Hide thumbs Also See for WIRELESS ALARM SYSTEM:
Table of Contents

Advertisement

2 2
2 2
4 4
ZZ
ZZ
Exit(OP)/Entry
+
03
03
Zone type Exit(OP)/Entry behaves like zone type Exit/Entry 1 except that the zone does
not have to be closed at the moment of activation. However, the zone must be closed
before the exit delay time expires, or otherwise there is an alarm. This zone type is usually
assigned to opening contacts on front and side doors.
Entry follower
2 2
2 2
4 4
ZZ
ZZ
+
04
04
Zone type Entry follower does not trigger an alarm if an entry delay time is started first. If
no entry delay is active, this zone triggers an alarm immediately if the area is activated. This
zone type is usually assigned to motion sensors that monitor the entrance area, in addition
to opening contacts on the entrance doors.
Instant
2 2
2 2
4 4
ZZ
ZZ
+
05
05
If the area is active, the Instant zone type triggers an alarm immediately when the zone is
opened. This zone must not be opened during the entry and exit delay period. This is the
usual zone type for motion and opening sensors that are not in the entrance area.
I+Exit/Entry 1
2 2
2 2
4 4
ZZ
ZZ
+
(Interior + Exit/Entry 1)
06
06
The I+Exit/Entry 1 zone type is similar to zone type Exit/Entry 1. However, this zone type
is not monitored for an internally activated system.
IMPORTANT INFORMATION:
To shorten the exit delay time, press
this zone is now opened, there is an immediate alarm.
I+Exit/Entry 2
2 2
2 2
4 4
ZZ
ZZ
+
Interior+Exit/Entry 2)
07
07
See above. However, for zones of this type, the times of Group 2 apply.
I+Exit(OP)/Entry
2 2
2 2
4 4
ZZ
ZZ
+
(Interior+Exit(OP)/Entry)
08
08
The I+Exit(OP)/Entry zone type is similar to zone type Exit(OP)/Entry. However, this zone
type is not monitored for an internally activated system.
I+Entry follow
2 2
2 2
4 4
ZZ
ZZ
+
(Interior+Entry Follower)
09
09
The I+Entry follow zone type is similar to zone type Entry Follower. However, this zone
type is not monitored for an internally activated system.
Default for zone 1
Default for zone 2
twice. This sets the entry delay time to 0. If
Armed/internal
Armed/internal
Armed/internal
Armed
Armed
Armed
Armed
7-43