Connecting Stations; Cautions For Connecting Stations; Table 7.1 Distance Between Stations And The System - Samsung OfficeServ 7400 Installation Manual

Hide thumbs Also See for OfficeServ 7400:
Table of Contents

Advertisement

CHAPTER 7.
Additional Equipment
This chapter describes how to connect various stations and additional equipment, such as
analog/digital phones, door phones and door locks, to the OfficeServ SME system.

7.1 Connecting Stations

7.1.1 Cautions for Connecting Stations

Take the following cautions when connecting stations:
Do not connect stations in weather conditions such as storm and lightning.
Do not connect stations in a humid area.
Comply with the manual of the station and with this document when reconnecting
stations or changing connections.
Connect stations to a pair of #24 AWG or #26 AWG cables.
The distances between stations and the OfficeServ SME system are as follows:
Digital Phone
Analog Phone
Door Phone
AOM
WBS24
© SAMSUNG Electronics Co., Ltd.
Connecting Stations and

Table 7.1 Distance Between Stations and the System

Station
OfficeServ 7400 Installation Manual
Distance
Maximum 400 m(for AWG #24)
Maximum 1000 m(for AWG #24)
Maximum 400 m(for AWG #24)
Maximum 400 m(for AWG #24)
Maximum 600 m(for 0.64 twisted cable)
Maximum 400 m(for 0.40 twisted cable)
7-1