Chapter 1. Before Installing; Site Information - Samsung OfficeServ 7400 Installation Manual

Hide thumbs Also See for OfficeServ 7400:
Table of Contents

Advertisement

CHAPTER 1.
This chapter describes items to check when inspecting the installation site and the
grounding and power conditions before installing the OfficeServ 7400 system. This chapter
also describes the items included in the OfficeServ 7400 package and the installation
procedure.

1.1 Site Information

Select a site that satisfies the following conditions for safety, temperature and humidity:
Safety Conditions
The OfficeServ 7400 system should not be installed near materials that can cause a fire,
such as explosive gas and inflammables.
The OfficeServ 7400 system should not be near equipments that generate electromagnetic
waves, such as monitors or copying machines.
The installation location should be convenient for distributing trunk lines and
extension lines, for connecting power and grounding wires, and for maintenance and
repair.
The OfficeServ 7400 system should not be installed in aisles or passageways that are
populated or used for moving equipment.
Always maintain cleanliness to prevent dust from damaging the board-connecting part
of the cabinet.
Before installing the OfficeServ 7400 system, check items such as the electrical wiring
status, grounding status, voltage and frequency.
Temperature and Humidity
The conditions for temperature and humidity are as follows:
− Operation Temperature: 0~45°C
− Storage temperature: -10~50°C
− Humidity: 10~90%
− Cool area without direct sunlight
Ventilators should be installed to remove dust.
© SAMSUNG Electronics Co., Ltd.
Before Installing
OfficeServ 7400 Installation Manual
1-1

Hide quick links: