Connecting Stations And Additional Equipment; Connecting Stations - Samsung OfficeServ 7200 Technical Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

OfficeServ 7200
TECHNICAL MANUAL
PART 7. CONNECTING STATIONS AND
ADDITIONAL EQUIPMENT
This section describes how to connect various stations and additional equipment, such
as analog/digital phones, door phones and door locks, to the OfficeServ 7200 system.

7.1 CONNECTING STATIONS

7.1.1 Safety Precautions
To reduce the risk of personal injury, follow these precautions before connecting
telephone circuits:
• Never install telephone wiring during a lightening storm.
• Never install telephone jacks in a wet location unless the jack is specifically
designed for wet locations.
• Do not connect stations in a humid area.
• Never touch non-insulated telephone wires or terminals unless the telephone line
has been disconnected at the network interface.
• Connect stations using #24 AWG or #26 AWG cables.
The maximum distance between stations and the OfficeServ 7200 are as follows:
Digital phone
Analog phone
Door phone
AOM
WBS24
7.1.2 Connecting an Analog Phone
Connect an analog phone to the 8SLI, 16SLI2, 16MWSLI, 8COMBO board installed in
the OfficeServ 7200 system.
CONNECTING TO THE 8SLI BOARD
Connect an analog phone to the 8SLI board by using a twisted pair of AWG #24 or AWG
#26 wire.
Table 7.1 Distance Between Stations and the System
Station
7.1
Home Page
PART 7 SEPTEMBER 2005
Distance
Maximum 400 m/1312 ft (for AWG #24)
Maximum 1 km/3280 ft (for AWG #24)
Maximum 400 m/1312 ft (for AWG #24)
Maximum 400 m/1312 ft (for AWG #24)
Maximum 600 m/1968 ft (0.64 twisted cable)
Maximum 400 m/1312 ft (0.40 twisted cable)
Table of Contents