Cyclo Vac motors do not require lubrication. Each motor contains two carbon
brushes that will wear normally, and may eventually require replacement. For
warranty purposes, replacement should be done by an authorized dealer. Brush
life is affected by hours of use, frequency of start-ups and shut-downs, humidity,
altitude, and temperature. In order to avoid damage to the unit's motor, brushes
should be replaced before they are completely worn-out. We recommend that you
have your unit and motors inspected by an authorized dealer every 5-6 years.
(Patented)
(Except models 95, 115, 215 & 615)
We recommend changing this filter after three
bag replacements or after 45 hours of use. For
the DL, GX & HX series, the DataSync monitor
will indicate when to change the filter. These
indications are provided by an electronic timing
board only as a reference guide. To do so:
1. Unlatch the opening on the carbon filter case
and gently lift it upward (figure 8).
2. Remove the used filter, and discard (figure 9).
3. Insert the new filter. When doing so, ensure
that the arrow printed on the filter itself points
outwards. (figure 10).
4. Close casing, and latch.
Part number: TDFILHEC2
Periodical maintenance of the dirt receptacle is necessary to ensure constant,
lasting performance. We recommend that it be emptied every season, depending
on frequency of use. To do so, disconnect your vacuum from its power source.
Then, release the two clamps, empty the recipient and reseal it in place.

Carbon Dust Filter

Dust Receptacle

Maintenance

Motor

figure 8
figure 9
21