APPENDIX
4.4.1
Main menu
The details of the different menu points of the main menu are described below.
Menu point:
1 Ackn. failure
2 Operat. mode
2 Cy permeate
4 Temp. permeate
5 Hour meter
6 Cy limits
7 Optional alarm
8 Calibration
9 Setting
10 Diagnosis
86
Function:
This menu point allows to acknowledge an operating failure
(the only possibility if ps acknowledgement = with password).
This menu point allows to change the operating mode by means of a
selection. For safety purposes, selection only can be made between
STOP and OPERATION as well as STOP and DISINFECTION
respectively (direct change-over from OPERATION to DISINFECTION
is not possible).
Permanent display of current permeate conductivity. To leave this menu
point press one of the keys.
Permanent display of current permeat temperature. To leave this menu
point press one of the keys.
Calling-in (display) of the operating hours meter.
Numerical entry of LIM and aaLIM.
Setting (selection) of ps LIM high
This menu point assures branching to the calibration menu (see item
4.4.3). The new calibration will be stored if the entered data are
acknowledged before leaving the calibration menu.
This menu point assures branching to the setting menu (see item 4.4.4).
The modification will be stored of the entered data are acknowledged
before leaving the setting menu.
This menu point assures branching to the diagnosis menu (see item
4.4.5). At the beginning of the diagnosis, all actuators of the unit are
switched off. The sytem returns to the previous status if diagnosis is
completed.
WTC 600 LP / MP
Service Handbook 08.2004