Putting Out Of Operation - Kärcher WATERCLEAN 600 CD Service Handbook

Karcher water system user manual
Table of Contents

Advertisement

WTC 600 LP / MP
3.4.5

Putting Out of Operation

CAUTION
Normally, do not switch off with the main switch (a possibly active flushing program
may be interrupted).
NOTE
The RO system working in normal operation is switched off only via the float switch
when the drinking water tank is full.
The current operating mode is also maintained in the switched off condition, meaning
NOTE
after switching on again, the control system is in the same operating mode as before
switching off last with the main switch.
The system is switched off e. g., when putting out of operation for extended periods. For out-of-
operation periods exceeding 14 days, the equipment must be conserved (see Chapter 4.4.4).
Enter user password for this (compare with Chapter 3.4.3.1):
Indication:
Press the
pushbutton.
Indication:
Press the RETURN pushbutton.
Indication:
Press the
pushbutton.
Indication:
Press the RETURN pushbutton.
Indication:
Press the
pushbutton.
Indication:
Press the RETURN pushbutton.
Indication:
Press the ESC pushbutton.
Indication:
The equipment is switched off now.
Service Handbook 08.2004
OPERATION OF THE SYSTEM
> 1 ackn. failure <
2 operat. mode
1 ackn. failure
> 2 operat. mode <
operation mode
OPERATION
operation mode
Stop
are you sure ?
>no<
yes
are you sure ?
no
> yes <
1 ackn. failure
> 2 operat. mode <
RO 1000 V 01.34
Stop
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Waterclean 600 lpWaterclean 600 mpWaterclean 600 pi

Table of Contents