Kärcher WATERCLEAN 600 CD Service Handbook page 59

Karcher water system user manual
Table of Contents

Advertisement

WTC 600 LP / MP
4.5.4
Malfunctions – Media and Activated Carbon Filter, Fine Filter and Flocculation
Indication
Malfunction
More than one
Backwashing is
backwashing
initiated too often
per day
(diagnosis
controller)
Backwashing no
sufficient
Sand
conglutinated
Differential
Filtrate of the sand
pressure of
filter turbid
fine filter quickly
exceeds 1 bar
Filtrate of the
activated carbon
filter turbid
Filter material
conglutinated
Indication of the
controller
remains dark
Control wheel
does not stand
still
No changes of Backwashing is
the "back-
not initiated
washing"
counter
Tabelle 31
Service Handbook 08.2004
Cause
Corrective Action
Load of debris
Install suitable preliminary 3.4.2.4
too high
treatment; consultation
through sales
Pump defective
Replace pump or
repair
Intake side of
Clean
pump clogged
Intake side of
Shorter line set-up;
pump too long
notify sales
Heavily soiled
Notify sales
water
Small particles
Install preliminary
come through
treatment
Small particles
Check sand filter;
come through
install preliminary
treatment as required
No backwashing Carry out backwashing;
carried out for too if without success,
long
replace sand
Too much
Reduce metering amount
flocculation agent of flocculation agent;
added
carry out backwashing
Power supply
Notify electrician
disconnected
Control switch or Replace controller
switching
mechanism
defective
Controller
Change
incorrectly
programming
programmed
MAINTENANCE
Chap./Fig.
Tab. 24
4.1
4.1
3.4.2.1
3.4.2.4
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Waterclean 600 lpWaterclean 600 mpWaterclean 600 pi

Table of Contents