MAINTENANCE
4.5

Malfunction, Cause and Corrective Action

4.5.1

Metering Station LED and Indicator LEDs at the Switch Cabinet

Indication
Malfunction
Red fault LED
Pump in metering
lights
station blocked
Red
regeneration
LED lights
Red tank full
Float switch in the
LED lights
drinking water tank tank full
has switched
Table 27
Malfunction indications at the switch cabinet and their causes
Indication
Malfunction
Green LED at
LED does not
metering station flash when
pump does not high-pressure
flash
pump runs
Red LED at
Pump blocked
metering
station pump
lights red
Table 28
Metering station and metering pump LED
56
Cause
Corrective Action
Metering
Refill, check float switch
container empty
Sensor signal
Check sensors,
missing
check bridges in
switch cabinet,
check sensor
wiring
Backwashing of
Not necessary, as
the sand filter or
the equipment
activated carbon automatically
filter active
switches on again
Drinking water
Not necessary, as
the equipment
automatically
switches on again;
Switch defective Check switch, replace if
necessary
Cause
Corrective Action
No power supply Have fuse Q2
checked from
electrician
Operating mode
Set operating mode switch (1/10)
contact
to manual
Electrical defect
Replace pump
Metering
Refill, check float switch
container empty
Cable that
Have cable checked
indicates empty
is broken
Auxiliary
Have auxiliary contactor
contactor in
replaced by electrician
switch cabinet
defective
WTC 600 LP / MP
Chap./
Fig.
2.3.1.5,
3.2,3.3.2.4
2.3.1.5,
ETL, 3.3.2
2.3.1.5
2.3.1.5,
3.3.2.4
Chap./
Fig.
ETL
3.2,
3.3.2.4
3.3.2.3
ETL, SLP
Service Handbook 08.2004