Kärcher WATERCLEAN 600 CD Service Handbook page 54

Karcher water system user manual
Table of Contents

Advertisement

MAINTENANCE
System
Volume of
output [l/h]
disinfectant
solution [l]
600
30
Table 26
Composition of the disinfectant solution
10. Flush the service kit with drinking water
11. Switch the RO system to run operating mode.
4.4.7
Replace the activated carbon or filter sand
If the differential pressure at the pre-filters does not reduce despite flushing the filter medium
(cf. Chap. 4), the filter material must be replaced.
Auxiliaries:
- Wet-dry vacuum NT 602 ECO 1.408-151.0
- 4 metal suction pipes, 0.5m
(Remove the plastic rings from the metal pipes)
- Filling funnel
- Shovel
Spare parts required:
- Activated carbon filter bed
- Sand filter bed
Spare parts possibly required:
- Filter pressure tank
- Set of O-rings
Initial situation:
- WTC 600 set to switched off operating mode and switched off at the master switch
- Untreated water pipe shut off
54
RMP3 Oxonia active
15% [l]
0,75
6.902-050.0
4.901-090.0
6.812-049.0
6.414-721.0
6.414-714.0
6.414-710.0
6.414-713.0
WTC 600 LP / MP
Art.-No.
6.294-010.0
Service Handbook 08.2004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Waterclean 600 lpWaterclean 600 mpWaterclean 600 pi

Table of Contents