Selecting Several Arguments At The Same; Adjusting Operating Parameters And Balancing Values; Acknowledging Data Inputs - Kärcher WATERCLEAN 600 CD Service Handbook

Karcher water system user manual
Table of Contents

Advertisement

WTC 600 LP / MP
3.4.3.4

Selecting Several Arguments at the Same

For this a series of "0" (argument inactive) and "1" (argument active) appears on the bottom line
of the display. With help of the
between the individual characters. The activation / inactivation of an argument is carried out with
the
pushbutton and the
RETURN pushbutton (Example: See Chapter 3.4.3.7).
3.4.3.5

Adjusting Operating Parameters and Balancing Values

For adjustment of operating parameters (e. g. via a menu), the name of the operating parameter
appears in the upper line and the current value is shown in the bottom line. A flashing cursor
marks the respective changeable figure, which can be adjusted to the desired value by pressing
the
pushbutton and the
the marking can be slid to the respective other figure. Storing is carried out through pressing the
RETURN pushbutton; the input can be cancelled by pressing the ESC pushbutton.
3.4.3.6

Acknowledging Data Inputs

To avoid input errors, acknowledgments are required at various menu locations. They request
the user again to acknowledge changes of operational settings / parameters and adjustments as
correct.
For acknowledgment the
pressed.
3.4.3.7
De-conserving
The RO system leaves the factory conserved. Therefore, the conservation liquid must be
flushed out before the initial startup.
Initial situation:
The pre-filters have been put into service. The filter insert has been inserted at the fine filter 5µ.
After all the water pipes and float switch have been connected, the drinking water pipe to the
tank must be undone and temporarily fed to the wastewater sewer.
Work steps:
- Master switch on: system is in switched off operating mode
- Temporarily lay the drinking water pipe in the sewer
- Flush / purge system:
- Pressure regulating valve (4.17) fully open (lever horizontal)
- Concentrate regulating valve (4.15) half open (45°).
The following message must be indicated on the display:
RO 1000 V 01.34
Otherwise press the ESC pushbutton 5 times.
Then enter user password (cf. Chap. 3.4.3.1).
Service Handbook 08.2004
pushbutton and the
pushbutton respectively. Storing is carried out through pressing the
pushbutton. With help of the
pushbutton and afterwards the RETURN pushbutton must be
Stop